Products
JSJ-GL-type climbing frame special instrument
First, the instrument function
To access the following functions, you need to enter a password.
Instrument has a key operating functions, when climbing frame adjustment is completed, press the CLS key is automatically set based on the current value of the instrument set and stop loss point.
1, the loss of load:
(1), with the loss of load switching function, set the function switch can be set to lose. 0 is off, 1 is on.
(2), loss of airborne early warning (85% of the current value): loss of airborne early warning can be freely set parameters, when the instrument reaches warning status, OUT1 relay is short, intermittent movement; buzzer sounded, the sound is short, intermittent sound, warning lights.
(3), loss of load (70% of the current value): set parameter can be set freely loss, loss of load when the instrument reaches the state, OUT1, OUT2 relay remains action; buzzer sounded, the sound is a long ring, loss of load indicator light onwards.
2, stop
(1), with the loss of load switching function, you can set the stop function switches. 0 is off, 1 is on.
(2), stop warning (15% of the current value): warning parameters can be set freely, when the meter reaches warning status, OUT1 relay is short, intermittent movement; buzzer sounded, the sound is short, intermittent sound, warning lights .
(3), stop (30% of the current value): overloaded parameters can be set freely, when the meter reaches overload condition, OUT1, OUT2 relay remains action; buzzer sounded, the sound is a long ring, overload indicator lights.