CFYH oilfield load sensor

Author:Anonymous Update:2013-7-11 Hits:0

Features and Uses

Sensor cartridge Charpy structure, internal seal 'has good dynamic performance, comprehensive, high precision, corrosion, dust, water, etc., can realize the wireless transmission function. Specifically for oil field pumping units, working conditions and control of automated test signal acquisition can be directly output a variety of standard signals can also be directly used for PLC or computer.


Dimensions



 
Technical Specifications (range 10t ~ 20t)




 

Parameters Units Technical parameters Parameters Units Technical parameters
Sensitivity mV / V 1.0 ~ 1.5 ± 0.05 Temperature coefficient of sensitivity ≤% F · S/10 ℃ ± 0.1
Nonlinear ≤% F · S ± 0.3 Operating temperature range -20 ℃ ~ +80 ℃
Hysteresis ≤% F · S ± 0.3 Input resistance Ω 750 ± 20Ω
Repeatability ≤% F · S ± 0.15 Output Resistance Ω 700 ± 5Ω
Creep ≤% F · S/30min ± 0.1 Safe overload ≤% F · S 150% F · S
Zero output ≤% F · S ± 1 Insulation resistance ≥ 2000MΩ (50VDC)
Zero temperature coefficient ≤% F · S/10 ℃ ± 0.1 Recommended excitation voltage V 10V ~ 15V