CFBLZ column pull pressure sensor (large range)

Author:Anonymous Update:2013-7-11 Hits:0

Features and Uses

Sensor column structure, with high accuracy, good strength, good stability characteristics. Widely used in crane scales, hopper scales and other industrial automation process control tension measurements.


Dimensions

Range ФA B C 2-M D
20t 60 180 64 M36 × 4 40
30t 76 213 73 M45 × 4.5 45
50t 94 332 112 M64 × 3 70
100t 112 367 130 M76 × 3 80


Technical Specifications

 

Parameters Units Technical parameters Parameters Units Technical parameters
Sensitivity mV / V 1.5 ± 0.05 Temperature coefficient of sensitivity ≤% F · S/10 ℃ ± 0.1
Nonlinear ≤% F · S ± 0.1 Operating temperature range -20 ℃ ~ +80 ℃
Hysteresis ≤% F · S ± 0.1 Input resistance Ω 400 ± 20Ω
Repeatability ≤% F · S ± 0.05 Output Resistance Ω 350 ± 5Ω
Creep ≤% F · S/30min ± 0.1 Safe overload ≤% F · S 150% F · S
Zero output ≤% F · S ± 1 Insulation resistance ≥ 5000MΩ (50VDC)
Zero temperature coefficient ≤% F · S/10 ℃ ± 0.1 Recommended excitation voltage V 10V ~ 15V