CFBHM bellows load sensor

Author:Anonymous Update:2013-7-11 Hits:0

Features and Uses

The sensor uses a pressure-sensitive flat membrane, shell and membrane integral structure, small size, reliable performance. Force and weight applicable to a variety of industrial automation control systems.


Dimensions

Range ФA B H Ф1 ФD 4-M SR
50kg ~ 5t 51 25 20 10 42 M5 SR50
6 ~ 10t 88 47 42 18 72 M6 SR150


Technical Specifications

 

Parameters Units Technical parameters Parameters Units Technical parameters
Sensitivity mV / V 1.0 ~ 1.5 ± 0.05 Temperature coefficient of sensitivity ≤% F · S/10 ℃ ± 0.1
Nonlinear ≤% F · S ± 0.3 Operating temperature range -20 ℃ ~ +80 ℃
Hysteresis ≤% F · S ± 0.3 Input resistance Ω 350 ± 50Ω
Repeatability ≤% F · S ± 0.3 Output Resistance Ω 350 ± 5Ω
Creep ≤% F · S/30min ± 0.1 Safe overload ≤% F · S 150% F · S
Zero output ≤% F · S ± 1 Insulation resistance ≥ 2000MΩ (50VDC)
Zero temperature coefficient ≤% F · S/10 ℃ ± 0.1 Recommended excitation voltage V 10V ~ 15V