Products
CFND dynamic torque sensor
Features and Uses
Dynamic torque sensor uses strain theory, high precision, stable and reliable performance, range large, easy to install. Connection at both ends were selected according to site needs flanged connections Quartet keys, key (through slot) connection
Dimensions
Specifications (NM) | Фd | ФD2 | A | B | C | E | F | G | H | H1 | L | Key b * h * l * n |
0 ~ 100 | 18 | 78 | 8 | 72 | 122 | 31 | 61 | 100 | 54 | 112 | 188 | 6 × 6 × 25 × 1 |
200 | 28 | 92 | 8 | 72 | 123 | 41 | 61 | 100 | 60 | 125 | 209 | 8 × 7 × 35 × 1 |
500 | 38 | 96 | 8 | 72 | 124 | 55 | 61 | 100 | 65 | 135 | 238 | 10 × 8 × 50 × 2 |
1K ~ 2K | 48 | 106 | 8 | 69 | 126 | 70 | 78 | 120 | 68 | 144 | 270 | 14 × 9 × 65 × 2 |
5000 | 75 | 144 | 13 | 69 | 132 | 105 | 85 | 120 | 90 | 185 | 347 | 20 × 14 × 95 × 2 |
10000 | 98 | 158 | 13 | 80 | 144 | 120 | 110 | 160 | 110 | 214 | 389 | 28 × 16 × 115 × 2 |
Technical Specifications (range 5N.m ~ 10000N.m)
Torque indication error | <± 0.5% F · S | Static Overload | 120% |
Nonlinear | <± 0.25% F · S | Temperature | 0 0 ℃ ~ 60 ℃ |
Repeatability | <± 0.2% F · S | Storage Temperature | -20 ℃ ~ 70 ℃ |
Backlash | <0.2% F · S | Supply Voltage | +15 V ± 5%;-15V ± 5% |
Zero point drift | <0.5% F · S | Total current consumption | <130mA |
Zero drift | <0.5% F · S/10 ℃ | Frequency signal output | 5KHZ ~ 15KHZ |
Output Impedance | 1KΩ ± 3Ω | Rated torque | 10KHZ ± 5KHZ (positive and negative bi-directional measurement) |
Insulation Resistance | > 500MΩ | Signal duty | (50 ± 10)% |