CH6 Series digital instrument

Author:Anonymous Update:2013-7-11 Hits:0

Features and Uses

Explanation 
① error is less than 0.5% FS, and have adjusted, digital filtering 
② Input signal type: universal input, by setting options; apply voltage, current, RTD, thermocouple signal 
③ Dimensions: 160 × 80 (horizontal / vertical), 96 × 96,96 × 48 (horizontal / vertical), 72 × 72,48 × 48 
④ Power: 220VAC ± 10%, power consumption less than 7VA 
(Note: 0 ~ 10VDC input, when ordering) 
Basic Configuration 
Single display, 2-point alarm, 24V external supply 
Extensions 
Transmitter output (transmitter output when there is no external supply 24V)

 

Technical Specifications

 
 
Content
Code
Explanation
CH6 /
Digital instrument
Dimensions
A-
160 (W) × 80 (H) × 125 (L) or 80 (W) × 160 (H) × 125 (L)
B-
96 (W) × 96 (H) × 76 (L)
C-
96 (W) × 48 (H) × 82 (L) or 48 (W) × 96 (H) × 82 (L)
D
72 (W) × 72 (H) × 75 (L)
E
48 (W) × 48 (H) × 108 (L)
Panel form
H
Horizontal
S
Vertical
F
Square
Display Color
R
Red
Alarm
T
2:00 alarm output
Transmitter output
A0
No transmission output
A1
Current output
A2
Voltage Output
External transmitter power supply
B0
No external power supply
B1
24V external supply
B2
12V external supply
The default appearance of the input signal
E
Thermocouple Input
R
RTD input
I
DC current
V